1 Citation
Introduction: Digitizing cytology slides presents challenges because of their three-dimensional features and uneven cell distribution. While multi-Z-plane scan is a prevalent solution, its adoption in clinical digital cytopathology is hindered by prolonged scanning times, increased image file sizes, and the requirement for cytopathologists to review multiple Z-plane images.
Methods: This study presents heuristic scan as a novel solution, using an artificial intelligence (AI)-based approach specifically designed for cytology slide scanning as an alternative to the multi-Z-plane scan. Both the 21 Z-plane scan and the heuristic scan simulation methods were used on 52 urine cytology slides from three distinct cytopreparations (Cytospin, ThinPrep, and BD CytoRich™ (SurePath)), generating whole-slide images (WSIs) via the Leica Aperio AT2 digital scanner. The AI algorithm inferred the WSI from 21 Z-planes to quantitate the total number of suspicious for high-grade urothelial carcinoma or more severe cells (SHGUC+) cells. The heuristic scan simulation calculated the total numbers of SHGUC+ cells from the 21 Z-plane scan data. Performance metrics including SHGUC+ cell coverage rates (calculated by dividing the number of SHGUC+ cells identified in multiple Z-planes or heuristic scan simulation by the total SHGUC+ cells in the 21 Z-planes for each WSI), scanning time, and file size were analyzed to compare the performance of each scanning method. The heuristic scan's metrics were linearly estimated from the 21 Z-plane scan data. Additionally, AI-aided interpretations of WSIs with scant SHGUC+ cells followed The Paris System guidelines and were compared with original diagnoses.
Results: The heuristic scan achieved median SHGUC+ cell coverage rates similar to 5 Z-plane scans across three cytopreparations (0.78-0.91 vs. 0.75-0.88, P=0.451-0.578). Notably, it substantially reduced both scanning time (137.2-635.0 seconds vs. 332.6-1278.8 seconds, P<0.05) and image file size (0.51-2.10 GB vs. 1.16-3.10 GB, P<0.05). Importantly, the heuristic scan yielded higher rates of accurate AI-aided interpretations compared to the single Z-plane scan (62.5% vs. 37.5%).
Conclusion: We demonstrated that the heuristic scan offers a cost-effective alternative to the conventional multi-Z-plane scan in digital cytopathology. It achieves comparable SHGUC+ cell capture rates while reducing both scanning time and image file size, promising to aid digital urine cytology interpretat...